技術(shù)熱線:13141412786
Email:info@oven.ccRapid-Rate Thermal Cycle Chamber
The Rapid-Rate Thermal Cycle Chamber is ideal for test requiring quick changes 15°C/min ramp rate in specimen temperature and 23°C/min ramp rate for air temperature(temperature heat up average). It covers various applications from JEDEC, IEC standards to screening.
It features new technologies, such as a specimen temperature control function maintaining linear specimen temperature change rates during rapid thermal cycling, and temperature ramp control.
Model | Temperature range | Inside / Outside dimensions (mm) |
---|---|---|
T/270/70/25 | -70 to +180°C (-94 to +356°F) | W580×H750×D615 / W895×H1950×D2080 |
IEC-60749-25 : Semiconductor devices – Temperature cycling
IEC-60068-2-14 Nb : Environmental testing – Change of temperature
IEC-61147-5 : Liquid crystal and solid-state display devices – Environmental, endurance and mechanical test methods
JESD22-A105-B : Solid State Devices, testing quality and reliability – Power and temperature cycling
SAE-J1211 : Automotive components - Recommended environmental practices for electronic equipment design
IPC-9701 : Performance test methods and qualification requirements for surface mount solder attachments
High precision of the specimen temperature control achieved thanks to a sensor for temperature specimen measurement, and the embedded high-speed controller.
In addition:
lead to excellent temperature ramp control.
Two temperature control modes are available:
Test standard | Temperature setting |
Temperature change rate |
Soak time |
Number of cycles |
||
---|---|---|---|---|---|---|
High temperature (°C) | Low temperature (°C) | |||||
IEC 60749-25 (JESD22-A104-D) |
G | +125 (+15, -0) | -40 (+0, -10) |
Specimen temperature, 15°C / min. or less |
1, 5, 10, 15 min. | Not specified |
I | +115 (+15, -0) | -40 (+0, -10) | ||||
J | +100 (+15, -0) | 0 (+0, -10) | ||||
K | +125 (+15, -0) | 0 (+0, -10) | ||||
L | +110 (+15, -0) | -55 (+0, -10) | ||||
N | +80 (+15, -0) | -30 (+0, -10) | ||||
O | +125 (+15, -0) | -25 (+0, -10) | ||||
IEC 60068-2-14 Nb (JIS C 60068-2-14 Nb) |
+175 ±2 +155 ±2 +125 ±2 +100 ±2 +85 ±2 +70 ±2 +55 ±2 +40 ±2 +30 ±2 |
-65 ±3 -55 ±3 -40 ±3 -25 ±3 -5 ±3 +5 ±3 |
1±0.2°C / min. 3±0.6°C / min. 5±1.0°C / min. (AVG) Average for up to fi ve minutes |
3 hours, 2 hours, 1 hour, 30 min., 10 min. 3 hours if not specified in product specifi cations |
2 | |
IEC-61747-5 (EIAJ ED-2531A) |
+100 ±2 +95 ±2 +90 ±2 +85 ±2 +80 ±2 +75 ±2 +70 ±2 +65 ±2 +60 ±2 +55 ±2 +50 ±2 +45 ±2 +40 ±2 +35 ±2 +30 ±2 |
-50 ±3 -45 ±3 -40 ±3 -35 ±3 -30 ±3 -25 ±3 -20 ±3 -15 ±3 -10 ±3 -5 ±3 -0 ±3 |
1±0.2°C / min. 3±0.6°C / min. 5±1.0°C / min. (AVG) Average for up to fi ve minutes |
3 hours, 2 hours, 1 hour, 30 min., 10 min. 3 hours if not specified in product specifi cations |
2 | |
JESD22-A105-B | A | +85 (+10, -0) | -40 (+0, -10) | 6.25°C / min. | 10 min. | 1000 |
B | +125 (+15, -0) | -40 (+0, -10) | 5.5°C / min. | |||
IPC-9701 | TC1 | 100 | 0 |
Specimen temperature, 20°C / min. or less |
Specimen temperature, 10 min. |
200 500 1000 3000 6000 |
TC2 | 100 | -25 | ||||
TC3 | 125 | -40 | ||||
TC4 | 125 | -55 | ||||
TC5 | 100 | -55 | ||||
IPC-TM-650 2.6.6 | A | +125 (+3, -0) | -65 (+0, -5) | - | 30 min. | 5 |
B | +85 (+3, -0) | -55 (+0, -5) | ||||
SAE-J1211 | +85 to +150 | -40 | 4 to 6°C / min. |
Low temperature, 4 hours |
- |